Polarimeter for laboratory and training

P1000-LED

Polarimeter P1000-LED

Polarimeter P1000-LED

Polarimeter glass tube PRG-100

Polarimeter glass tube PRG-100

Polarimeter glass tube PRG-200

Polarimeter glass tube PRG-200

Quartz control plates polarimeter PQP

Quartz control plates polarimeter PQP

Key features
Applications
Standards
Samples
Key features

Indispensable for teaching and training

Our polarimeter P1000-LED is used by numerous companies and institutes for basic lab applications and training, for example the experiment on saccharose inversion. It measures the optical rotation according to the half-shade principle, and the measurement results are read through an eyepiece and two noniuses.

  • Basic laboratory applications
  • Sample chamber for measurement tubes with a length of up to 220 mm
  • Requires only little maintenance due to a high performance LED whose service life is up to 2000 times longer than that of conventional sodium discharge lamps
  • The scope of delivery includes two measurement tubes (100 and 200 mm length) with a debubbler for the proper filling.
  • Can be validated due to the possibility of receiving quartz control plates for the calibration and adjustment.
Applications

Typical applications

Hospitals and pharmacies:

  • Incoming/outgoing goods inspection
  • Control of pharmaceutical products according to pharmacopoeias

Training in the industry or at universities:

  • Use for practical exercises and experiments:
  • Kinetics of the cane sugar inversion
  • Mutarotation of glucose
  • Determination of the concentration of polysaccharides through amylolysis

A comprehensive overview of typical applications with the polarimeters of the P8000 series can be found in our campus article on polarimeter applications.

Standards

Compliance with global standards

Working in accordance with standards and guidelines facilitates the comparison of the measured values and ensures their quality. The polarimeters P1000-LED meets the requirements of the following standards:

  • Pharmacopoeias (USP, BP, JP, Ph. Eur.)
  • ASTM
  • ICUMSA
  • NIST

Polarimeter Standards (PDF, 83 KB)

Get in contact with us, we will assist you in choosing a suitable polarimeter.

Samples

Welche Proben wollen Sie untersuchen?

The polarimeter P1000-LED is used in the laboratory, industry and research to measure a wide range of samples, eg. drugs, raw materials and auxiliaries. We have bundled our expertise in an overview of the samples that can be measured with our instruments.

For your free download:
(All values have been compiled with best accuracy, but this information is supplied without liability.)

Polarimeter samples and their optical rotation (PDF, 122 KB)

Do you have questions?
Get in contact with us, we will assist you in choosing a suitable polarimeter.

Model specifications

 P1000-LED
SCALEOptical rotation [°]
MEASUREMENT RANGE2 graduated circles (0–180°)
SCALE DIVISION
READING ACCURACY0.05° (with nonius)
LIGHT SOURCE1 LED with filter
WAVELENGTH589 nm

Technical data polarimeters (PDF, 490 KB)

Datasheet Polarimeter measurement tubes (PDF, 819 KB)

Strong in education and in simple laboratory applications

  • Training instrument for universities and schools
  • Very simple operation for measuring tasks with an accuracy specification of 0.05 °
  • Training use, for example, for the attempt to sucrose inversion
 

Fast, reliable measurement

  • Measurement of the optical rotation according to the half-shade principle
  • The results are read through an eyepiece and two noniuses.
 

Can be validated

  • This simple, analogue device can also be validated.
  • The sample chamber is adapted to receive our quartz control plates for the calibration and adjustment.
 

Easy filling and cleaning

  • Suitable measurement tubes for any type of sample
  • Various tube lengths can be used
  • Chemical-resistant and easy to clean materials
 

Low maintenance

  • High-performance LED whose service life is up to 2000 times longer than that of conventional sodium discharge lamps
  • High quality metal housing
 

Compliance with global standards

  • Pharmacopoeias (USP, BP, JP, Ph. Eur.)
  • ASTM
  • ICUMSA
  • NIST
 

Polarimeter glass measurement tube

Here you will find a wide selection of simple and tempered glass measurement tube for the entire range of applications. With temperature sensors PRT-E / PRT-T, they have a precise temperature measurement directly in the sample and are suitable for all samples, including aggressive chemicals.

Glass measurement tubes PRG
 

Our Campus

We share our experiences and expert knowledge: explore our campus and learn more about typical applications, standards and fields of applications, about sample behavior and functionality, about automation options, about calibration and adjustment, temperature control and temperature compensation. Embark on a journey of discovery with us.

Campus overview
 

Any Questions?

We will be glad to help.

A.KRÜSS Optronic GmbH
Alsterdorfer Str. 276-278
22297 Hamburg | Germany

Tel. +49 40 5143 17-0
Fax +49 40 5143 17-60

E-Mail sales@kruess.com