Melting point meter for semi-automatic measurements

M3000

Melting point meter M3000

Melting point meter M3000

Melting point meter M3000 with RS-232 interface

Melting point meter M3000 with RS-232 interface

Melting point meter M3000 with capillaries and ocular

Melting point meter M3000 with capillaries and ocular

Melting point calibration standards

Melting point calibration standards

Melting point meter capillaries

Melting point meter capillaries

Key features
Applications
Key features

Semi-automatic measurement using 10x observation optics

The M3000 provides fast and easy examination of powdery substances with a melting point up to 360 °C. Due to the triple capillary intake, it is possible to analyse three samples within one measurement run. Thanks to the preheating rate and the integrated fan cooling, fast measurements are possible in any temperature range. The display provides a wellarranged readout of all important measuring data.

  • Semi-automatic measurement
  • 3 capillary intakes
  • LCD-Display
  • Monitoring of the illuminated sample via lens
  • Fast cooling through integrated fan
  • Digital display of all important data
  • Display in German or English
  • With RS-232 interface for printer CBM910
  • Easy-to-clean membrane keypad
  • Includes protective cover and 100 capillaries
  • Small sample volume
Applications

Typical applications

The determination of the melting point is of great importance in the identity test, since many substances can be determined by their melting point.

The purity of substances can also be qualitatively measured via melting point. A well-defined melting point is only given for 100 percent pure substances. Due to impurities, such as impurities or dopants, most substances have a melting interval (beginning of the melt to completion of the melt) of a few degrees Celsius. Even impurities during the manufacture of chemicals cause this melting point to expand to a melting interval. As a result, most substances that are examined with a melting point meter have a melting interval. This effect is used to identify the degree of impurity of the substance.

Model specifications

 M3000
MEASUREMENT RANGE30–360 °C
MEASUREMENT ACCURACY±0.3 °C (30–200 °C)
±0.5 °C (200–360 °C)
RESOLUTION0.1 °C
PREHEATING RATETo 200 °C approx. 4.0 min
To 300 °C approx. 8.0 min
HEATING RATE1 °C min-1
OBSERVATION LENS10x
NO. OF CAPILLARIES3
CAPILLARY Ø1.4 mm
INTERFACERS-232
IP CODEIP20
POWER SUPPLY90–264 V
DIMENSIONS (W X H X D)210 mm x 360 mm x 230 mm
WEIGHT4.3 kg

Why should I invest in a semi-automatic melting point meter?

melting point

The modern melting point meter is fast and accurate, providing reproducible results which do not rely on the skill of the individual operator. Measurements can be printed for a permanent record. Digital control means that the sample is heated, the melting point recorded, and the apparatus cooled ready for the next sample is just a few minutes. Sample sizes are small, being just enough powdered material to fill a small capillary tube, and the output reading is accurate to within 0.3 – 0.5C with good reproducibility.

More in the application video

Calibration standards for melting point determination

Certified, traceable calibration standards for melting point determination

Calibration standards M3000 M5000
 

Any Questions?

We will be glad to help.

A.KRÜSS Optronic GmbH
Alsterdorfer Str. 276-278
22297 Hamburg | Germany

Tel. +49 40 5143 17-0
Fax +49 40 5143 17-60

E-Mail sales@kruess.com